Server QOS 8-Bay Guida Utente Pagina 141

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 308
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 140
Virtual Connect fabrics 141
The VC-FC and FlexFabric modules use dynamic login distribution to equally distribute server logins
across all available uplink ports. The port with the least number of active logins is used for server
connectivity. When the number of logins is equal, VC-FC or FlexFabric modules utilize a round-robin
technique.
The VC-FC and FlexFabric modules use dynamic login distribution to provide an uplink port failover
path that enables server connections to fail over within the VC SAN fabric. If a VC SAN fabric uplink
port becomes unavailable, servers logged in through that uplink are automatically reconnected using
one of the remaining uplinks in the VC SAN fabric, resulting in automatic failover.
When a previously failed uplink is reconnected to the fabric, no server logins on the VC-FC modules are
moved to the newly available port. This can cause an unbalanced situation where some uplink ports
have more server logins than others. When enabled for VC FlexFabric modules, Automatic Login
Vedere la pagina 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 307 308

Commenti su questo manuale

Nessun commento