Server QOS 8-Bay Guida Utente Pagina 218

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 308
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 217
Virtual Connect server profiles 218
4
Start with modules in Bays 3
and 4, create a profile (add
2 connections), install
modules into Bays 5 and 6,
then edit the profile.
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 3
4 Bay 4
Bay 3 Bay 4
Bay 5 Bay 6
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
This profile is not useful after
the hot-plug install. To resolve
this issue, delete connections 3
and 4, save the profile, and
then scenario 3 applies.
5
Start with modules in Bays
3–6, create a profile, install
modules into Bays 7 and 8,
then edit the profile and add
connections.
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
5 Bay 7
6 Bay 8
Add connection, 2 times
6
Start with modules in Bays
3–6, create a profile (add 4
connections), install modules
into Bays 7 and 8, then edit
the profile.
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
5 Bay 3
6 Bay 4
7 Bay 5
8 Bay 6
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
This profile is not useful after
the hot-plug install. To resolve
this issue, delete connections
5–8, save the profile, and then
scenario 5 applies.
7
Start with modules in Bays 5
and 6, create a profile,
install modules into Bays 3
and 4, then edit the profile.
Port Connected to
1 Bay 5
2 Bay 6
Bay 3 Bay 4
Bay 5 Bay 6
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
To make this profile useful,
remove the two connections,
save the profile, and then
begin adding connections.
8
Start with modules in Bays
5–8, create a profile, install
modules into Bays 3 and 4,
then edit the profile.
Port Connected to
1 Bay 5
2 Bay 6
4 Bay 7
5 Bay 8
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Add connection is disallowed
because the current FC module
configurations do not match
the existing connections in the
profile.
To make this profile useful,
remove the two connections,
save the profile, and then
begin adding connections.
Vedere la pagina 217
1 2 ... 213 214 215 216 217 218 219 220 221 222 223 ... 307 308

Commenti su questo manuale

Nessun commento